Dura-Shield Blast

Designed and Tested to Department of Defense Anti-Terrorism Standards.

The Dura-Shield Blast Doors have been developed in partnership with Insulgard® Security Products to provide protection from BLAST attacks.

A blast resistant door.

Product Details

  • Door panels constructed of heavy-duty aluminum-extruded 2 ½" x 6" (63.5mm x 152.4mm) framing
  • Heavy-duty aluminum-extruded framing can accommodate the widest range of glazing options in the industry
  • Door stiles assembled with threaded rods and clips + wall thickness of aluminum stiles and rails twice industry standard for unparalleled strength
  • Configurable for integration with building security systems
  • UL-Listed battery backup and fire alarm integration for emergency egress
  • Solenoid Lock – Electronic locking System
  • Dual motor drive system
  • Rotary Key Switch

 

Design 

Bi-Part, Single Slide

Breakout None
Finish Clear or Dark Bronze Anodized | Special Finishes Available
Header Size

11” (279mm) High x 8 7/8” (227mm) Deep

Bottom Rail Nominal 10"
Maximum Sizes Single Slide: 10’ 0” (3.0m) x 8’ 0“ (2.4m) | Bi-Part: 16’ 7” (5.08m) x 8’ 0“ (2.4m)
Clear Door Opening

Bipart: 68 5/8” | Single Slide 36 1/16” to 42 1/16”

Power Required 120 VAC, 50/60 HZ, 5 Amps Minimum | Uninterrupted Power Supply | Up to 1.5 Hours Supplemental Power
Drive System Two 1/4 HP DC Motors, Gear Drive, Toothed belt
Controls Rocker Switch | OPTION: Rotary, Keyed Rotary Controls, Eco Pro    
Controller High Resolution iQ Controller, Microprocessor Based, Safety Logic, Fire Alarm Interface, Position Encoder, Programmable Interface
Activation/Safety Sensors 2 Combined Activation/Safety Sensors + Doorway Holding Beams for added safety | OPTION: Wallplates, Radio Control, Touchless Activation, Badge Access
Locking Solenoid Lock (Electronic Locking System), Rotary Key Switch
Temperature Ratings -30F to 130F
Codes & Standards UL®, cUL, ANSI A156.10*, ASTM F2927, ASTM Category III, ASTM Glazing Hazard H2, GSA Classification C Performance 3a or 3b, UFC 4-010-01 – Department of Defense Code

*Due to extreme forces during a blast event, our Blast product complies with all facets of ANSI 156.10 except emergency egress breakaway. Please consider alternate egress routes when designing your life safety egress plan. Final use of this project must be approved by local Fire Marshall.

*All Specifications are subject to change. Please contact your local sales representative to ensure accuracy.

 